Bhavyam Engineering Technologies Pvt. Ltd.

Gas Flow Meter

Compact Orifice-Based Gas Flow Metering System — for natural gas, biogas, compressed air & other dry gases

Designed & engineered to
ISO 5167ASME MFC-3MAGA 3EN 10204 3.1
Gas flow meter — biogas metering assembly

Flow Metering Solutions

Gas Flow Meter

Our Compact Orifice-Based Gas Flow Metering System is an integrally engineered flow measurement solution designed for accurate, repeatable measurement of dry gases including Natural Gas, Biogas, Compressed Air, Nitrogen, and other process/utility gases. The system combines a compact orifice assembly with integral metering pipe sections and a direct-mounted multivariable transmitter — eliminating the impulse tubing, condensate pots, and manifold valves associated with conventional DP metering runs.

This integral construction significantly reduces installation footprint, potential leak points, and commissioning time, while the multivariable transmitter delivers live density, pressure, and temperature-compensated mass flow output from a single instrument.

Being a compact, self-contained metering run, the system is ideal for space-constrained installations, skid-mounted packages, and applications where a traditional flanged orifice run with separate impulse piping is impractical.

Specifications

  • Sized for actual operating pressure, temperature and gas composition for corrected mass / standard-volume flow.
  • Averaging pitot tube option for large ducts and low-pressure-drop installations.
  • BETLOCK manifolds and BETFITT fittings supplied as a complete impulse loop.
  • Flow straightening and upstream / downstream requirements per ISO 5167.

Technical specifications.

ParameterSpecification
Service Natural gas, biogas, compressed air, nitrogen & dry gases
Line size DN25 – DN350 (1"–14")
Pressure / temperature Up to 50 bar (g) / -20°C to +120°C
Output Multivariable 4–20 mA with HART; density-compensated
Supply Factory-assembled spool, calibrated as one unit
Metering principle Differential pressure; Bernoulli’s principle (ISO 5167-2 / ASME MFC-3M)
Gas type Dry gases — natural gas, biogas, compressed air, nitrogen, and similar non-corrosive gases
Line size range DN25 – DN350 (1"–14"), customizable per application
Pressure rating Up to 50 bar (g)
Process temperature -20°C to +120°C (standard range; extended range on request)
Orifice plate material SS316/316L (standard); other alloys on request
Metering pipe material Carbon steel / SS316L, as per line class
Tapping configuration Integral pressure ports, direct-connected to transmitter (no impulse tubing)
Multivariable transmitter output 4–20 mA with HART (Fieldbus/Profibus/Modbus optional)
Overall system accuracy ±1.0% to ±2.0% of measured flow (typical, application-dependent)
Turndown ratio Up to 4:1
Density compensation Real-time, via onboard multivariable computation
Hazardous area certification ATEX / IECEx / CSA / FM (as required)
Enclosure protection IP66 / IP67

Key features engineered in.

  • Integral, compact design — orifice, metering pipe, and transmitter form a single mountable spool piece, minimizing footprint and leak points
  • No impulse lines or condensate pots — direct-mount transmitter eliminates wet/dry leg issues common to remote DP installations
  • Live density compensation — multivariable transmitter continuously corrects for pressure and temperature variation, critical given the variable composition of biogas and other process gases
  • Suitable for multiple dry gas services — natural gas, biogas, compressed air, nitrogen, and other non-corrosive/dry gas streams
  • Reduced installation & commissioning time — factory-assembled and calibrated as a single unit, reducing field welding, tubing, and leak-testing
  • High reliability — no moving parts, no impulse tubing to freeze, block, or leak

Applications we serve.

  • Biogas flow measurement (digester gas, landfill gas, CHP feed)
  • Natural gas custody transfer and process metering
  • Compressed air flow measurement (utility & instrument air)
  • Nitrogen and other inert gas metering
  • Fuel gas measurement for boilers, burners, and gensets
  • Gas distribution and plant utility monitoring

Need help with your flow measurement challenge?

Share your fluid properties, line size, flow rate and operating conditions � our engineers respond with sizing, drawings and a quotation.